Clinical Study
Technical Feasibility of TachoSil Application on Esophageal Anastomoses
Table 3
Time-action score form for the harmonica technique of TachoSil application on esophagojejunostomy after laparoscopic total gastrectomy.
| Action | Effectiveness | Number of actions () | Duration (s) |
| Folding TachoSil patch into harmonica shape | Success/failure | | | Grasping TachoSil patch | Success/failure | | | Inserting surgical instrument with TachoSil patch through trocar | Success/failure | | | Moving TachoSil patch to location of anastomosis | Success/failure | | | Turning TachoSil patch 180 (yellow side at the bottom) | Success/failure | | | Placing TachoSil at anastomotic tissue | Success/failure | | | Unfolding TachoSil patch | Success/failure | | | Applying pressure at TachoSil patch | Success/failure | | | Leaving TachoSil at anastomotic site | Success/failure | | | Adherence of complete TachoSil patch | Success/failure | | |
|
|