Research Article

Value of Magnifying Chromoendoscopy and Magnifying Optical Enhancement Technology in Classifying Colorectal Polyps: A Prospective Controlled Study

Table 3

Diagnostic accuracy and time in two methods.

Overall
ME-OE
ME-CE
ME-OE
ME-CE
Stage 1
Stage 2
Stage 1
Stage 2

Sensitivity (%)918596908784
Specificity (%)95968519398
PPV (%)94948619396
NPV (%)929095938892
Accuracy (%)939290969093
value0.6390.1450.418
0.8590.8270.8040.9120.8000.848
Time (s)
value0.0010.0010.001