Review Article

Review on Characterization, Properties, and Analytical Methods of Cefepime

Table 2

Micellar electrokinetic chromatographic methods for determination of CP.

TechniqueColumn (C)Mobile phase or eluentConditionsMatricesReference

MEKCUncoated FSC of 50 μm6 mM Na2B4O7, 10 mM Na2HPO4, 75 mM SDS pH 9.1257, V of 15 kVHuman serum and plasma[50]
MEKCUncoated FSC of 40.2 cm × 50 μm idTris with SDS : MeOH214, V of 15 kVPlasma and cerebrospinal fluid[51]
MEKCUncoated FSC of 31.2 cm (21 cm × 675 mm ID)10 mM tris buffer pH 8.0 + 150 mM SDS and 20 mM tris buffer pH 9.0 + 200 mM SDS254, V was 8 kVPlasma and cerebrospinal fluid[52]
MEKCBare FSC of 50 µm, 5 mmol with length 56 cmImidazole buffer pH 5.1240, V of 25 kVNMP in CP for injection[53]
MEKCUncoated FSC length 31.2 cmTris buffer + SDS as an electrolyte solution214, V of 15 kVCommercial injections[54]
MEKC + indirect UVMEKC [A 50 lm i.d 64.5 cm (56 cm detection length) bare FSC]
IC [Gel IC-Cation-SW C (4.6 50 mm, 5 lm) supported by a water’s cation GC (4.6·50 mm, 10 lm)]
MEKC (10 mM creatinine pH 3.8)
IC (ACN: 0.01 mM nitric acid) (1 : 100)
225
MEKC (V of 30 kV)
IC (1)
NMP in CP for injection[55]
CZEFSC (48.6 cm × 50 µm i.d.) with 40.2 cm as a detection length 40.2 cm)15 mm sodium borate buffer pH 9.3215, V was 20 kVPharmaceutical formulations and
human plasma
[56]

(ml/min); (nm).