Review Article

Review on Characterization, Properties, and Analytical Methods of Cefepime

Table 3

Potentiometric and electrochemical methods for assay of CP.

Technique’s nameSolvents/ConditionsMatricesReference

PH potentiometry264 and 230
Dilution with UB (0.1 M CH3COOH + 0.1 MH3PO4 + 0.1 MH3BO3)
Pharmaceutical preparation[57]
Electrochemical reduction and oxidationWE (glassy carbon electrode), RE (AgCl), AE (platinum wire)
The solutions were prepared in water and diluted with electrolytes
Pharmaceutical preparation[58]
Electrochemical ReductionA saturated AgCl (RE), WE (dropping mercury electrode), AE (glassy carbon) PB pH 2.7 (adjusted by 1 MH3PO4 + 1 M NaOH)Pharmaceutical formulations and human urine samples[59]
ASV + DPPRE (Ag/AgCl/saturated KC), WE (dropping-mercury electrode), AE (platinum wire)
For urine or plasma (PB pH 5.8), for serum (1 MH3PO4 and 1 M KOH pH 2.7) 0.1 M KCl used as ionic strength
Human urine, cerebrospinal fluid, and Serum[60]