Research Article
Development of a Colloidal Gold Immunochromatographic Strip for the One-Step Evaluation of the Total Content of Rhein and Aloe-Emodin in Rhubarb
Table 2
Comparison of analytical performances of CGIC strips for rhein and aloe-emodin with other reported methods.
| Analytes | Methods | Detection limit/cutoff value (ng mL−1) | Detection time (min) | Sample pretreatment | Test cost | Organic reagent | Reference |
| Rhein and aloe-emodin | HPLC | 7.8∼17.9 | 20 | Tedious | Expensive | Necessary | [11] | Rhein and aloe-emodin | UPLC | 40∼60 | 3 | Tedious | Expensive | Necessary | [12] | Rhein and aloe-emodin | CE | 500∼1230 | 10 | Tedious | Expensive | Necessary | [13] | Rhein and aloe-emodin | 1H NMR | 980∼2020 | 10 | Tedious | Expensive | Necessary | [14] | Rhein and aloe-emodin | NIS | -a | 64 | Simple | Expensive | Unnecessary | [15] | Rhein | ELISA | 20 | 70 | Simple | Economical | Unnecessary | [17] | Rhein | QD-LCS | 80 | 10 | Simple | Economical | Unnecessary | [18] | Rhein and aloe-emodin | CGIC strips | 50 | 6 | Simple | Economical | Unnecessary | This work |
|
|
aNot detected.
|