Standard deviation and relative spread using piezo pressure method at 25 mm.
| Test ammo # | Mean of 10 fired rounds | Piezo pressure [MPa] | Standard deviation [MPa] | Max value [MPa] | Min value [MPa] | Relative spread (%) |
| 1-NATO | 317.28 | 4.73 | 326.8 | 310.95 | 5.09 | 2-NATO | 316.2 | 3.75 | 322.7 | 309.55 | 4.24 | 3-NATO | 308.125 | 4.54 | 317.8 | 304.3 | 4.43 | 1-NSTD | 327.675 | 4.99 | 336.95 | 320.9 | 5.00 | 2-NSTD | 319.305 | 5.50 | 326.25 | 307.5 | 6.09 | 3-NSTD | 316.775 | 10.63 | 329.7 | 297.5 | 10.82 |
|
|