Table 1

Main parameters of FIS of the ECU pump.

TitleParameterValve

PlungerPlunger diameter (mm)13
Cam profile velocity (mm/CaA)0.46

InjectorOpening pressure (MPa)19
Maximum needle lift (mm)0.4
Flow (ml/())1500
Orifice number8
Orifice diameter (mm)0.26

High-pressure oil pipeLength (mm)900
Internal diameter (mm)2

Solenoid valveRod diameter (mm)6.98
Maximum rod lift (mm)0.21
Solenoid valve residue air gap (mm)0.12
Mass of moving parts (g)14.5