Research Article

Prediction of High-Cycle Fatigue Performance of 1Cr11Ni2W2MoV Stainless Steel Plate after Foreign Object Damage

Table 2

HCF limit of notched specimens.

No.Diameter (mm) (mm) (mm) (mm) (MPa)

121.690.960.43615
221.660.790.5776
332.771.340.82667
432.51.310.99658
532.871.561.04637
632.651.211.26610
732.520.961.11761
832.771.341.39599
932.541.191.49600
1032.571.111.22814
1143.541.691.94507
1242.851.061.61607
1343.411.61.56567

: HCF limit.