Research Article

Effect of Dimple Depth-Diameter Ratio on the Flow and Heat Transfer Characteristics of Supercritical Hydrocarbon Fuel in Regenerative Cooling Channel

Table 2

The thermal parameters of dimples with different depth-diameter ratios.

CaseMass flux (kg/m2) (K)Rein

Case 10.16253002924
4004151
5008355
60017522

Case 20.26253002924
4004151
5008355
60017522

Case 30.36253002924
4004151
5008355
60017522

Case 40.46253002924
4004151
5008355
60017522