Details about the mesh parameters in five cases.

Case 1Case 2Case 3Case 4Case 5

Cell number in solid domain (106)383.2383.2383.2383.2383.2
Cell number in fluid domain (106)178.1305.4621.51125.32041.3
1st grid thickness0.0010.0010.0010.0010.001