Research Article

Study on Heat Exchange Structure Design and Propulsion Performance of Solar Thermal Thruster

Table 3

Boundary conditions of 3D steady-state CFD simulation.

ZoneBoundary typeValue

InletMass flow rate
Pressure0.8 (MPa)
OutletPressure0
Radiation wallTemperature2400 K
Convection wallConvective heat transfer coefficient10 (W/m2K)
InterfaceCoupled\