Research Article
Analyses of the Design of Multirows Vaneless Staggered Counter-Rotating Turbine
Table 1
Staggered counter-rotating model turbine performance requirements.
| | HPT | LPT |
| Inlet total pressure/MPa | 0.5 | | Inlet total temperature/K | 400 | | Speed/RPM | 20124 | 13111 | Mass flow/kg/s | 3.72 | 3.72 | Work/kW | >280 | >180 | Total-total adiabatic efficiency | 0.9 | 0.9 | Outlet flow angle/deg | <25 |
|
|