Research Article

Experimental and Theoretical Study of Internal Pressure Loads on Boundary Walls under Gusty Wind Conditions

Table 3

Variation of as a function of the nominal gust frequency, , vent hole radius, , and volume of the air reservoir, .

(mm)0.501.502.505.007.009.0010.0011.0012.50
(Hz)

2.41013.6113.941.210.15.33.22.52.11.7
4.01719.8189.769.117.38.85.34.33.52.8
6.02575.1288.1103.925.913.38.06.55.44.2
7.73312.6367.7132.833.416.910.38.36.95.3
2.4517.457.520.95.22.61.61.31.10.8
4.0848.694.434.18.54.32.62.11.81.4
6.01286.4143.451.112.96.63.93.22.72.0
7.71623.7180.865.316.28.35.04.13.42.6
2.4295.632.211.73.01.50.90.70.60.5
4.0478.353.019.14.82.41.51.21.00.8
6.0722.080.629.17.23.72.21.81.51.2
7.7910.4101.336.79.14.72.82.31.91.5
2.4153.417.36.21.50.80.50.40.30.3
4.0255.728.510.12.61.30.80.60.50.4
6.0386.942.715.33.92.01.21.00.80.6
7.7488.854.119.54.92.51.51.21.00.8
2.476.08.43.00.80.40.20.20.20.1
4.0122.813.75.01.20.60.40.30.30.2
6.0187.920.87.61.91.00.60.50.40.3
7.7238.726.59.62.41.20.70.60.50.4