Research Article

Experimental and Theoretical Study of Internal Pressure Loads on Boundary Walls under Gusty Wind Conditions

Table 5

Negative pressure jumps. Values of the total pressure loss coefficient, , and flow coefficient, , as a function of the nominal gust frequency, , and vent hole radius , 11, and 12.5 mm; reservoir volume , 0.011 m3, 0.0062 m3, 0.0033 m3, and 0.0016 m3.

(mm)9.0011.0012.50
(Hz)

2.412.90.2416.50.2417.20.24
4.05.00.357.10.358.00.35
6.01.90.503.40.504.10.50
7.71.40.512.70.513.80.51
2.429.40.2438.60.2451.20.14
4.012.30.3515.10.3523.40.21
6.06.10.508.70.5015.80.25
7.75.00.518.60.5112.40.28
2.454.70.2476.00.24112.40.09
4.025.80.3536.80.3545.20.15
6.015.40.5028.50.5026.10.20
7.713.10.5120.30.5124.70.20
2.4254.40.24273.90.24365.50.05
4.097.40.35118.20.35163.90.08
6.046.50.5049.70.5066.10.12
7.738.20.5144.00.5156.70.13
2.435590.2474830.24111310.01
4.010140.3527230.35100320.01
6.03760.509500.5013190.03
7.72870.516390.519070.03