Research Article

Effects of Geometry of Plenum Chamber on Losses in the Bleed System of an Axial Compressor

Table 2

Comparison of numerical simulation and experimental results.

Experiment [20]CFD

Pressure ratio1.301.3069
Corrected mass flow rate (kg/s)13.413.406