Research Article
Theoretical and Experimental Study on Rapid Decompression Oscillation in Altitude Chamber
Table 1
Orthogonal experimental design.
| Test | Factor A | Factor B | Factor C | Differential pressure |
| ① | 15 kPa | 75 kPa | 800 mm | 60 kPa | ② | 10 kPa | 70 kPa | 800 mm | 60 kPa | ③ | 5 kPa | 65 kPa | 800 mm | 60 kPa | ④ | 3.1 kPa | 63.1 kPa | 600 mm | 60 kPa | ⑤ | 7.56 kPa | 45.20 kPa | 600 mm | 34.50 kPa | ⑥ | 15 kPa | 65 kPa | 600 mm | 50 kPa | ⑦ | 15 kPa | 70 kPa | 500 mm | 55 kPa | ⑧ | 31 kPa | 89 kPa | 500 mm | 58 kPa | ⑨ | 17.5 kPa | 58 kPa | 500 mm | 40.5 kPa |
|
|