Research Article
Theoretical and Experimental Study on Rapid Decompression Oscillation in Altitude Chamber
Table 2
Orthogonal experimental design.
| Test | Pipe diameter | Differential pressure | Equilibrium pressure | Decompression time | Maximum oscillation value |
| ① | 800 mm | 60 kPa | 16.17 kPa | 121 ms | 0.32 kPa | ② | 800 mm | 60 kPa | 11.18 kPa | 128 ms | 0.21 kPa | ③ | 800 mm | 60 kPa | 6.18 kPa | 115 ms | 0.76 kPa | ④ | 600 mm | 60 kPa | 4.28 kPa | 133 ms | 0.71 kPa | ⑤ | 600 mm | 34.5 kPa | 8.30 kPa | 143 ms | 0.54 kPa | ⑥ | 600 mm | 50 kPa | 15.98 kPa | 139 ms | 0.56 kPa | ⑦ | 500 mm | 55 kPa | 16.08 kPa | 209 ms | 0.51 kPa | ⑧ | 500 mm | 58 kPa | 32.14 kPa | 170 ms | 1.46 kPa | ⑨ | 500 mm | 40.5 kPa | 18.29 kPa | 188 ms | 0.66 kPa |
|
|