Research Article
Study on the Cavitation Suppression Mechanism of Axial Piston Pump
Table 1
Geometric parameters of fluid domain model.
| Parameters | Value | Parameters | Value |
| Number of plungers | 9 | The height of the top region (m) | 0.0450 | Plunger chamber radius (m) | 0.01 | Radius of the top region (m) | 0.0075 | The thickness of window region (m) | 0.0094 | The outer diameter of valve plate fluid field (m) | 0.0445 | The radius of the overflow region (m) | 0.012 | The inner diameter of the valve plate fluid domain (m) | 0.0365 | The radius of expansion and compression region (m) | 0.01 | Type of relief groove | Triangle |
|
|