Table 1

Geometric parameters of fluid domain model.

ParametersValueParametersValue

Number of plungers9The height of the top region (m)0.0450
Plunger chamber radius (m)0.01Radius of the top region (m)0.0075
The thickness of window region (m)0.0094The outer diameter of valve plate fluid field (m)0.0445
The radius of the overflow region (m)0.012The inner diameter of the valve plate fluid domain (m)0.0365
The radius of expansion and compression region (m)0.01Type of relief grooveTriangle