Research Article

Damage Initiation Analysis of a Tension Stiffened Composite PRSEUS Panel Based on Modified Hashin Criteria

Table 1

Three-stringer panel stack orientation.

Panel’s componentStack orientation with respect to the panel’s length

Skin(90)
Stringer(0, 0)
Frame cap(90, 90, 90)
Frame(0, 0, foam, 0, 0)