Table 6
Comparison of strain-load results in the simulated gages.
| Strain gage | Test value [16] | Standard analysis | Margin of error (%) | UMAT analysis | Margin of error (%) |
| 1A-S | 0.0024 | 0.0026 | 8.33 | 0.0025 | 4.16 | 2A-S | 0.0026 | 0.0028 | 7.69 | 0.0027 | 3.84 | 3A-F | 0.00175 | 0.0019 | 8.57 | 0.0018 | 2.85 | 3B-F | 0.0026 | 0.0027 | 3.84 | 0.00257 | 1.15 | 4B-F | 0.0026 | 0.0025 | 3.84 | 0.0025 | 3.84 | 5A-S | 0.0018 | 0.00192 | 6.66 | 0.00184 | 2.22 |
|
|