Research Article
Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter
Table 2
35 Hz basic parameter analysis.
| Location | Data number | Frequency band range (MHz) | Dominant frequency (MHz) | Corresponding amplitude (dBμV/m) |
| Near the output power cable of converter | 018 | 0–50 | 2.38 | 99.70 | 10.10 | 86.00 | 20.20 | 77.80 | 30.90 | 65.70 | 44.40 | 55.60 | 023 | 0–20 | 2.31 | 94.30 | 10.30 | 80.70 | 16.20 | 81.50 | 027 | 20–200 | 32.50 | 82.30 | 42.70 | 75.10 |
| Near the input power cable of converter | 022 | 0–20 | 2.22 | 85.56 | 11.30 | 78.82 | 14.33 | 83.77 | 17.71 | 77.36 | 026 | 20–200 | 27.43 | 84.46 | 33.70 | 74.64 | 44.65 | 65.38 |
| Output connecting motor cable close to the motor side | 020 | 0–50 | 2.39 | 95.16 | 9.74 | 85.38 | 20.17 | 83.42 | 33.28 | 65.87 | 025 | 0–20 | 2.48 | 89.22 | 9.70 | 75.24 | 13.90 | 80.08 | 028 | 20–200 | 20.39 | 76.48 | 24.70 | 75.44 | 34.48 | 74.14 | 41.91 | 68.76 |
|
|