Research Article
Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter
Table 3
20 Hz basic parameter analysis.
| | Location | Data number | Frequency band range (MHz) | Dominant frequency (MHz) | Corresponding amplitude (dBμV/m) |
| | Near the output power cable of converter | 008 | 0–20 | 2.40 | 92.10 | | 10.27 | 74.15 | | 14.98 | 80.68 | | 007 | 0–50 | 2.28 | 96.39 | | 10.16 | 85.19 | | 14.74 | 86.76 | | 20.71 | 76.89 | | 42.97 | 69.87 | | 0032 | 0–50 | 2.73 | 97.50 | | 10.49 | 88.31 | | 21.14 | 80.25 | | 31.07 | 66.54 | | 41.00 | 56.25 | | 013 | 20–200 | 21.96 | 79.51 | | 41.91 | 70.61 |
| | Near the input power cable of converter | 004 | 0–50 | 2.28 | 67.08 | | 11.33 | 67.34 | | 14.85 | 74.47 | | 17.08 | 66.26 | | 26.88 | 56.16 | | 012 | 20–200 | 27.04 | 73.61 | | 35.26 | 64.09 |
| | 3 m from the converter | 009 | 0–20 | 0.58 | 60.85 | | 2.44 | 57.00 | | 4.86 | 50.01 | | 010 | 0–20 | 2.48 | 51.03 | | 4.77 | 45.11 |
| | Output connecting motor cable close to the motor side | 006 | 0–50 | 2.39 | 98.09 | | 9.63 | 88.12 | | 19.90 | 83.44 | | 26.70 | 71.40 | | 33.00 | 65.07 |
|
|