Research Article

Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter

Table 3

20 Hz basic parameter analysis.

LocationData numberFrequency band range (MHz)Dominant frequency (MHz)Corresponding amplitude (dBμV/m)

Near the output power cable of converter0080–202.4092.10
10.2774.15
14.9880.68
0070–502.2896.39
10.1685.19
14.7486.76
20.7176.89
42.9769.87
00320–502.7397.50
10.4988.31
21.1480.25
31.0766.54
41.0056.25
01320–20021.9679.51
41.9170.61

Near the input power cable of converter0040–502.2867.08
11.3367.34
14.8574.47
17.0866.26
26.8856.16
01220–20027.0473.61
35.2664.09

3 m from the converter0090–200.5860.85
2.4457.00
4.8650.01
0100–202.4851.03
4.7745.11

Output connecting motor cable close to the motor side0060–502.3998.09
9.6388.12
19.9083.44
26.7071.40
33.0065.07