Equivalent Test Method for Strong Electromagnetic Field Radiation Effect of EED
Table 3
Ignition excitation test data of EED under continuous wave at 300 MHz.
E(V/m)
i
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
85
3
0
95
2
1
0
105
1
0
0
1
0
115
0
0
0
0
1
1
1
0
125
−1
0
1
1
1
1
0
0
135
−2
0
1
0
1
1
145
−3
1
1
1
The test data were analyzed by the Bruceton method and combined with equations (8)–(12). E0 = 115 V/m, d = 10 V/m, n = 14, A = −1, B = 27, M = 1.9, and b = 0.1. The 50% ignition field strength of EED is calculated: E50 = 115.0 V/m. Standard deviation: σ = 39.8 V/m.