Research Article

Electromagnetic Shielding Techniques in the Wireless Power Transfer System for Charging Inspection Robot Application

Table 2

The parameters of the experiment.

ParametersPrimary sideSecondary side

Frequency85 kHz
Distance50 mm
Real power2.46 kW1.968 kW
Self-inductance (sim)360.81 μH91.476 μH
Self-inductance354.76 μH94.7 μH
Resonant capacitance10.1 nF37 nF
Resistance0.341 Ω0.407 Ω
Number of turns16 × 224 × 2