Research Article

An Improved Power-Only Measurement Strategy for Calibrating Phased Array Antennas

Table 2

The initial excitations of all elements.

Element number1234567891011

Amplitude (dB)0−0.451.321.130.150.370.26−0.88−0.6−0.09−0.81
Phase (°)067−114−4745101−15115599−5−23