Research Article
Effects of Disinfection Methods on the Color Stability of Precolored and Hand-Colored Maxillofacial Silicone: An In Vitro Study
Table 2
Mean and standard error of color change (∆E) for four disinfection methods regardless of the type of intrinsically colored silicone.
| Disinfectant | Mean | Standard error | n | Post hoc test (Tukey HSD test) | Pair | value |
| Distilled water (DW) | 0.55 | 0.05 | 20 | DW/CHX | <0.001 | 2% chlorhexidine solution (CHX) | 1.77 | 0.13 | 20 | DW/CHXS | <0.001 | Chlorhexidine liquid soap (CHXS) | 1.27 | 0.11 | 20 | DW/AS | 0.136 | Antibacterial liquid soap (AS) | 0.83 | 0.09 | 20 | CHX/CHXS | <0.001 | | | | | CHX/AS | <0.001 | CHXS/AS | 0.006 |
|
|