Research Article

Treatment of Distillery Industrial Wastewater Using Ozone Assisted Fenton’s Process: Color and Chemical Oxygen Demand Removal with Electrical Energy per Order Evaluation

Figure 6

Effect of COD on % COD removal and EE/O in the O3/Fe2+/H2O2 process (experimental conditions: reaction time–4 h; O3 flow rate and production–20 LPM and 4 g/h; H2O2–100 mM; Fe2+–20 mM; and pH–6).