Research Article

Numerical Study to Define Initial Thermal Integration Window for Methane Oxidative Coupling with Dehydroaromatization Reactors

Table 8

Design parameters of autothermal coupled reactors according to targets in Table 7 and capacities in Figure 9.

Showcase #ReactorLdtubeTubesWcatεdUoverallTpTLΔP/PinƮXCH4XO2SC2/C6YC2/C6
cmcmkgs%W/m2.K°C°C%sec%%%%

1OCM1003.010001230120084.3013.60.352.810078.241.3
MDA18.5666709.360.30.91.311.118.42.0

2OCM10018.4100012348.625070.800.29.551.899.977.540.1
MDA25.9666709.459.90.91.311.018.22.0

3OCM5018.4200012348.625071.100.19.551.899.977.540.2
MDA25.9666709.559.90.31.311.018.32.0

4OCM20018.450012348.625069.700.19.551.699.977.540.0
MDA25.9666708.559.90.31.311.018.02.0

5OCM2511.61000012348.625044.716.50.19.542.399.569.529.4
MDA16.46667010.458.50.11.311.017.92.0

6OCM2009.2200012348.625037.927.00.69.538.71006525.1
MDA12.9666710.758.04.71.311.117.72.0

7OCM10020.6100011549.020083.300.212.052.010077.740.4
MDA27.5666709.560.70.91.311.018.22.0