Research Article

Evaluating the Optimal Operating Table Height for ProSeal-LMA™ Insertion

Table 3

Comparing different operating table height positions in determining successful first attempt P-LMATM insertion and its related individual positional and performance test.

U (n = 46)R (n = 46)X (n = 46) value value#

First attempt P-LMA™ insertion24 (52.2)37 (80.4)22 (47.8)0.002U vs. R: 0.004
U vs. X: 0.677
R vs. X: 0.001
Gastric tube “bubble” test44 (95.7)43 (93.5)39 (84.8)0.236U vs. R: 1.000
U vs. X: 0.158
R vs. X: 0.180
Suprasternal notch test31 (67.4)38 (82.6)26 (56.5)0.025U vs. R: 0.092
U vs. X: 0.283
R vs. X: 0.007
Gastric tube insertion test39 (84.8)42 (91.3)32 (69.6)0.021U vs. R: 0.335
U vs. X: 0.082
R vs. X: 0.009
Peak airway pressure test (≥25 cm H2O)27 (58.7)37 (80.4)25 (54.3)0.020U vs. R: 0.023
U vs. X: 0.674
R vs. X: 0.008
No audible leak40 (87.0)43 (93.5)36 (78.3)0.105U vs. R: 0.485
U vs. X: 0.271
R vs. X: 0.036

Data were presented as number of patients (percentage). value < 0.05 denotes statistical significance. # value < 0.0167 denotes statistical significance with Bonferroni correction.