Research Article

A Practical Model for Predicting Esophageal Variceal Rebleeding in Patients with Hepatitis B-Associated Cirrhosis

Table 3

LR and XGBoost models performance parameters.

ModelsAUCSensitivitySpecificityAccuracyPrecisionRecallF1

LR (6 W)0.828 (0.759–0.897)1.0000.570.602 (0.543–0.660)0.1571.0000.271
LR (1 Y)0.799 (0.738–0.860)0.6230.8480.799 (0.748–0.844)0.5280.6230.589
XGBoost (6 W)0.985 (0.907–0.731)1.0000.9070.914 (0.866–0.949)0.4851.0000.653
XGBoost (1 Y)0.931 (0.806–0.935)0.9570.8140.849 (0.791–0.895)0.6160.9570.750

LR (6 W): logistic regression model predicts rebleeding within 6 weeks; LR (1 Y): logistic regression model predicts rebleeding within 1 year; XGBoost (6 W): XGBoost model predicts rebleeding within 6 weeks; XGBoost (1 Y): XGBoost model predicts rebleeding within 1 year.