Research Article

High-Score US-Suspicious Subcentimeter Thyroid Nodules: What Factors Affect Adequate Sampling of US-Guided Fine-Needle Aspiration Biopsy?

Table 2

Adequate sample rate in relation to nodule-related factors.

VariableNo. of adequate sampling casesTotal no. of casesAdequate sample rate (%)P value

Nodule size (mm)0.007
 3–68011072.7
 7–1020323984.9

Nodule location0.916
 Right14117282.0
 Isthmus81080
 Left13416780.2

Composition0.312
 Solid26932981.8
 Mixed142070

Shape0.244
 Ovoid to round8411076.4
 Taller than wide566586.2
 Irregular14317482.2

Margin0.589
 Defined10012182.6
 Ill-defined18322880.3

Echogenicity0.705
 Hypoechoic24830481.6
 Isoechoic253375.8
 Hyperechoic101283.3

Calcification<0.001
 None9610690.6
 Microcalcification14818281.3
 Macrocalcification396163.9

aA statistically significant difference in diagnostic yield between nodules without calcification and nodules with either microcalcification () or macrocalcification () and nodules with microcalcification and macrocalcification ().