Research Article
Modeling and Performance Analysis of a Grid-Connected Photovoltaic System with Advanced Controller considering Varying Environmental Conditions
Table 5
THD comparisons of the proposed system with existing grid-connected systems.
| Author | Inverter | Control method | Conversion type | %THD |
| Kumar et al. [22] | Reduced switch asymmetric MMI | PSO-GA-based P&O | Two stage | 3.70% | Sriram and Nagaraja [25] | T-type three-level inverter | P&O | Two stage | 3.18% | Kumar et al. [26] | Reduced switch modular MLI | Fuzzy logic P&O | Two stage | 3.08% | Proposed | NPC inverter (case 1) | PSO-based P&O | Single stage | 1.67% | NPC inverter (case 2) | PSO-based P&O | Single stage | 1.74% | NPC inverter (case 3) | PSO-based P&O | Single stage | 1.61% | Proposed | NPC inverter (case 1) | AGO-RNN-based P&O | Single stage | 1.54% | NPC inverter (case 2) | AGO-RNN-based P&O | Single stage | 1.55% | NPC inverter (case 3) | AGO-RNN-based P&O | Single stage | 1.59% |
|
|