Research Article
Design and Thermal-Hydraulic Evaluation of Integrated Steam Generator with Serpentine-Tube Configuration for Prevention of Sodium-Water Reaction
Table 2
Design specifications of the S-ISG with a thermal capacity of 96.77 MWth.
| Design parameter | Value |
| Total length of a tube (sum of straight parts) (m) | 40.74 | Total number of hot tubes (per unit) (ea) | 190 | Total number of cold tubes (per unit) (ea) | 190 | Number of tubes in a row (ea) | 5 | Number of tube rows (ea) | 76 | Number of serpentine tube passes (ea) | 12 | Spacing between flow-guide walls (m) | 3.39 | Height between tube bending parts (m) | 0.9 | Height of heat transfer bundle (m) | 5.297 | Outer diameter of tube (mm) | 27.2 | Thickness of hot tube (mm) | 1.65 | Thickness of cold tube (mm) | 2.90 | Inclined angle of straight tube (°) | 3 | Pitch-to-diameter ratio (P/D) (-) | 1.5 | Total heat transfer area (per unit) (m2) | 1322.8 | Overall unit size () (m3) | |
|
|