Research Article

Design and Thermal-Hydraulic Evaluation of Integrated Steam Generator with Serpentine-Tube Configuration for Prevention of Sodium-Water Reaction

Table 3

Heat transfer and thermal-fluidic information for S-ISG.

ParameterValue (upregion)Value (downregion)

Target heat transfer rate (MWth)96.77
Sodium heat transfer rate (MWth)50.6246.23
LBE heat transfer rate (MWth)3.653.70
Water heat transfer rate (MWth)47.8449.06
Sodium mass flow rate (kg/s)522.9
Sodium inlet temperature (°C)510.8510.0
Sodium outlet temperature (°C)359.2371.5
Sodium pressure drop (kPa)124.2124.2
Steam/water mass flow rate (kg/s)43.1
Water inlet temperature (°C)216.9217.3
Steam outlet temperature (°C)463.8481.4
Steam/water pressure drop (kPa)17.017.1
LBE mass flow rate (kg/s)160.0
LBE temperature at top (°C)494.0494.0
LBE temperature at bottom (°C)333.2332.8
LBE pressure drop (kPa)0.1680.167