Design and Thermal-Hydraulic Evaluation of Integrated Steam Generator with Serpentine-Tube Configuration for Prevention of Sodium-Water Reaction

Table 4

Comparison of SPINS-S code results with the CFD analysis results for thermal-hydraulic conditions of S-ISG.

FluidVariableSPINS-SCFD
UpDownUpDown

Hot tube (Na)Inlet temp. (°C)510.8510.0510.0510.0
Outlet temp. (°C)359.2371.5350.5371.2
Pressure drop (kPa)124.2124.2174.7174.6
Cold tube (H2O)Inlet temp. (°C)216.9217.3217.0217.0
Outlet temp. (°C)463.8481.4484.3499.8
Pressure drop (kPa)17.017.114.217.6
Shell (LBE)Topside temp. (°C)494.0494.0501.3501.3
Bottom temp. (°C)333.2332.8320.6320.6
Heat transfer rate (MWth)96.85 (sodium)/96.91 (water)99.69 (sodium)/99.63 (water)