Design and Thermal-Hydraulic Evaluation of Integrated Steam Generator with Serpentine-Tube Configuration for Prevention of Sodium-Water Reaction

Table 5

Comparison of the SPINS-S code with the CFD analysis results for inlet and outlet temperatures of all tubes in S-ISG.

FluidVariableTube no.

Upregion12345
Hot tube (Na)Inlet temp. (°C)SPINS-S512.0511.7511.5509.8508.7
CFD510.0510.0510.0510.0510.0
Outlet temp. (°C)SPINS-S360.1360.5360.5359.4355.4
CFD346.1350.8351.7352.3351.5
Cold tube (H2O)Inlet temp. (°C)SPINS-S216.9216.9216.9216.9216.9
CFD217.0217.0217.0217.0217.0
Outlet temp. (°C)SPINS-S457.8465.9468.2467.0460.0
CFD485.0485.3485.3484.1481.9
Downregion12345
Hot tube (Na)Inlet temp. (°C)SPINS-S510.0510.0510.0510.0510.0
CFD510.0510.0510.0510.0510.0
Outlet temp. (°C)SPINS-S379.7370.6368.0368.1371.1
CFD369.0371.0371.4371.6372.9
Cold tube (H2O)Inlet temp. (°C)SPINS-S215.0216.8218.1218.5218.2
CFD217.0217.0217.0217.0217.0
Outlet temp. (°C)SPINS-S479.3478.8479.7482.2487.0
CFD500.4499.7499.6499.6499.9