The comparison of various P&O algorithm.

AlgorithmStep irradiance decrease (500 W/m2 to 300 W/m2)
Step irradiance increase (300 W/m2 to 500 W/m2)
Tracking time (mS)Deviation (W)Oscillation (W)Tracked power (W)

Conventional P&O3503214.50
6007.8220.00

Conventional INC3402.7214.55
5807.5220.05

VSS P&O3202.51.514.90
42091.520.25

ASS INC2504.5114.70
35012120.30

Modified P&O2801.50.215.50
30070.221.00

Proposed P&O2600.80.215.50
2706.80.221.00