Research Article

Performance and Loss Analysis of a Small-Scale Supercritical CO2 Turbine

Table 4

Grid independence verification.

GroupGrid numberTotal (%)
StatorRotor

1192,300137,160329,46056.10
2519,240343,920863,16056.45
31,082,040721,8001,803,84057.25
41,454,5201,031,0402,485,56057.41
52,854,9802,097,9004,952,88057.62