Research Article

Determination of Flowing Electrolyte Parameters in a Zinc-Air Fuel Cell by the Taguchi Method

Table 3

Experimental data.

Num.Temperature (°C)Concentration (wt%)Flow rate (ml/min)Spacing (mm)Result 1 (mA/cm2)Result 2 (mA/cm2)Result 3 (mA/cm2)

13030505471.869428.302409.043
230401008449.671375.143369.969
3305015010375.480369.968363.926
4403010010431.983369.969369.769
540401505460.777444.309431.764
64050508449.817430.700428.303
750301508688.637540.874525.131
850405010551.860466.597449.818
950501005597.889540.874519.352

Note: (reaction area is 35 cm2).