TCSC Application for Transient Stabilization of Wind Turbine with Fixed Speed Induction Generator

Table 6

Comparison of proposed and conventional schemes in facing different situations.

The ratio of the fault distance from the IG terminal to the length of the transmission line (%)
Clearance time (ms)5101520253035404550556065707580859095

150TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP
155TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP
160TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP
165TTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP
170TTPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP
175TTPTPTPTPTPTPTPTPTPTPTPTPTPTP
180TTPTPTPTPTPTPTPTPTPTPTPTPTP
185TTPTPTPTPTPTPTPTPTPTPTPTP
190TTPTPTPTPTPTPTPTPTPTPTPT
195TTTPTPTPTPTPTPTPTPTP
200TTPTPTPTPTPTPTPTPT
205TTTPTPTPTPTPT
210TTTTPTPTPT
215TTTT
220TT
225

TP: both TCSC and pitch angle solutions can ride through the IG from fault; T: only TCSC solution can ride through the IG from fault; P: only pitch angle solution can ride through the IG from fault.