Revealing the Impact of High Current Overcharge/Overdischarge on the Thermal Safety of Degraded Li-Ion Batteries
Table 2
Test procedures settings.
Test type
Test procedures
Reference performance test (25°C)
(1) Constant current (CC) charging to 4.2 V under 1/3C and then constant voltage (CV) charging under 4.2 V until current decreased to <1/20C (2) Rest for 30 mins (3) Discharging to 2.5 V at 1/3C (4) Rest for 30 mins Note: The reference performance test lasts for three cycles.
2C cycling at 25°C