Curve parametersChangeDegradation mode

ICShifting to a lower voltageConductivity loss (CL)
DVShifting to a lower capacityLoss of lithium inventory (LLI)
ICDecrement of the valley magnitudeLAM
DVIncrement of the peak magnitudeLAM