Research Article

A BP-IPSO Algorithm Suitable for Centralized Thermoelectric Generation System Power Tracking under Nonuniform Temperature Distribution

Table 4

Error evaluation index calculation results.

MethodRMSEMAEMAPE

P&O3.71892.49380.0288
PSO2.17731.23170.0208
GWO1.94450.97910.0125
BP-IPSO0.50710.26780.0060