Performance analysis-comparison results.
| Algorithm | Cases | Iterations | Convergence time (s) | Power at GM (W) | Power tracked (W) | Efficiency (%) |
| P&O | Pattern1 | — | 0.05 | 798, 557.8, 227.3 | 790, 550,223 | 98.20 | Pattern2 | — | — | 504.2 | 440.5 | 87.36 | Pattern3 | — | — | 322.2 | 265 | 82.24 |
| SGO | Pattern1 | 7 | 0.75 | 798, 557.8, 227.3 | 797.5, 557.3, 226.8 | 99.91 | Pattern2 | 10 | 0.8 | 504.2 | 503.5 | 99.86 | Pattern3 | 12 | 0.82 | 322.2 | 321.5 | 99.78 |