Research Article
Comparative Performance Study of Dissolved Gas Analysis (DGA) Methods for Identification of Faults in Power Transformer
Table 16
Performance accuracy comparison of each DGA method.
| Total cases | Roger’s ratio method | IEC ratio method | Doernenburg ratio method | Duval triangle method | Three-ratio method | Relative percentage of four gas methods | Key gas method |
| Number of total predictions | 22 | 22 | 22 | 22 | 22 | 22 | 22 | Total right predictions | 15 | 16 | 11 | 18 | 20 | 17 | 19 | Total wrong predictions | 7 | 6 | 11 | 4 | 2 | 5 | 3 | Total accuracy | 68% | 72% | 50% | 81% | 90% | 77% | 86% |
|
|