Parameters of the permanent magnet tubular linear generator.

Parameters (unit)Value

Resistance of stator (ph-ph) (Ω)12.8
Inductance of stator (pH-pH) (mH)26
Force constant (N/A)56
Max stator current (A)20
Max stroke (m)0.07
Pole pitch (m)0.02
Back EMF constant (ph-ph) (V/(m/s))41
Flux linkage of permanent magnets (Wb)0.27