Research Article
Performance Characteristic of Permanent Magnet Linear Generator for Energy Conversion with Renewable Fuels on Free-Piston Engines
Table 4
Comparison of test and simulation results under different operating conditions.
| Frequency (Hz) | Stroke (m) | Peak voltage of experiment (V) | Peak voltage of simulation (V) | Error (V) | Relatively error (%) |