Research Article

Performance Characteristic of Permanent Magnet Linear Generator for Energy Conversion with Renewable Fuels on Free-Piston Engines

Table 4

Comparison of test and simulation results under different operating conditions.

Frequency (Hz)Stroke (m)Peak voltage of experiment (V)Peak voltage of simulation (V)Error (V)Relatively error (%)

140.01017.1517.240.090.52
120.06586.9991.694.705.40
100.07076.4482.315.877.68
80.02521.4023.311.918.93
60.04529.4531.682.237.57
40.03517.2117.640.432.50
20.06013.8815.171.299.30