Research Article

A Concept of Online Refueling TRISO-Fueled and Salt-Cooled Reactor

Table 6

Effect of control rod material on reactivity.

MaterialHot state (operation condition)Cold state (300 K for all components)
Reactivity
(pcm)
Reactivity
(pcm)
SDM OSRª (pcm)

He1.01336+1,3181.06639+6226
B4C0.89635-11,5640.94342-5998-4557
Gd2O30.91920-8,7900.96985-3108-2112
AgInCd0.91912-8,8000.97037-3053-2098
Hf0.91636-9,1270.96665-3450-2438
Inconel slug0.98897-1,1151.03571+3448+3674
SS3040.99694-3071.04314+4136+4367

ªShutdown margin with one stuck rod.