The thermal-hydraulic codes incorporate various condensation models [3, 154].

No.AbbreviationTypeCondensation model

1GOTHICLP/CFDUchida correlation and Gido and Koestel correlation (HMTD)
2COCOSYSLPStefan law (HMTA)
ASTECLP
3CONTAINLPCollier’s model (HMTA)
PCCSACCFD
CONTEMPT-LTLP
COMMIX-1DCFD
4MAAP-DBALPUchida and Tagami correlations
COMPACTLP
5GASFLOWCFDChilton-Colburn analogy (HMTA)
6CONTEMPT-4/MOD5LPTagami correlations and other
7MELCORLPCollier’s mass flux and Chilton-Colburn correlation (HMTA)
8TONUSLP/CFDChilton/Bird condensate rate formulation with McAdams correlation (HMTA)
9RELAPLPColburn-Hougen model (HMTA)
10CFX-4CFDNonimplemented
FLUENTCFD