Research Article
Optimal Sizing and Management of Hybrid Wind Turbine-Diesel-Battery System for Reverse Osmosis Seawater Desalination in NEOM City
Table 7
Detailed output for different components of the WT/DG/BS system.
| Quantity | Value | Unit | Quantity | Value | Unit |
| Wind turbine | Total rated capacity | 90.0 | kW | Maximum output | 47.6 | kW | Mean output | 12.2 | kW | Wind penetration | 48.8 | % | Capacity factor | 13.5 | % | Hours of operation | 3,377 | hrs/yr | Total production | 106,783 | kWh/yr | Levelized cost | 0.209 | $/kWh | Diesel generator | Hours of operation | 4,791 | hrs/yr | Electrical production | 119,068 | kWh/yr | Number of starts | 992 | starts/yr | Mean electrical output | 24.9 | kW | Operational life | 3.13 | yr | Minimum electrical output | 6.25 | kW | Capacity factor | 54.4 | % | Maximum electrical output | 25.0 | kW | Fixed generation cost | 2.41 | $/hr | Specific fuel consumption | 0.306 | L/kWh | Marginal generation cost | 0.273 | $/kWh | Fuel energy input | 358,747 | kWh/yr | Fuel consumption | 36,458 | L | Mean electrical efficiency | 33.2 | % | Battery storage | Autonomy | 4.03 | hr | Batteries | 48.0 | qty. | Storage wear cost | 0.221 | $/kWh | Energy in | 25,255 | kWh/yr | Nominal capacity | 126 | kWh | Energy out | 21,478 | kWh/yr | Usable nominal capacity | 101 | kWh | Storage depletion | 12.0 | kWh/yr | Lifetime throughput | 109,685 | kWh | Losses | 3,789 | kWh/yr | Expected life | 4.71 | yr | Annual throughput | 23,296 | kWh/yr | Converter | Hours of operation | 1,608 | 2,382 | Energy in | 21,478 | 26,585 | Energy out | 20,404 | 25,255 | Losses | 1,074 | 1,329 |
|
|